1887
Rapid communications Open Access

Abstract

We report a fatal case of community-acquired Legionnaires' disease in an infant aged under six months. Epidemiological and microbiological investigations suggested that a free-standing cold water humidifier using domestic tap water contaminated with Legionella pneumophila serogroup 1 served as a vehicle for infection. These findings were corroborated by sequence-based typing (SBT). Humidifier-associated Legionnaires' disease can be prevented by appropriate control measures. This case also illustrates the emerging role of SBT in the investigation of legionellosis.

Loading

Article metrics loading...

/content/10.2807/ese.17.41.20293-en
2012-10-11
2024-12-26
/content/10.2807/ese.17.41.20293-en
Loading
Loading full text...

Full text loading...

/deliver/fulltext/eurosurveillance/17/41/art20293-en.htm?itemId=/content/10.2807/ese.17.41.20293-en&mimeType=html&fmt=ahah
Submit comment
Close
Comment moderation successfully completed
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error