1887
Rapid communications Open Access
Like 0

Abstract

We present two real-time reverse-transcription polymerase chain reaction assays for a novel human coronavirus (CoV), targeting regions upstream of the E gene (upE) or within open reading frame (ORF)1b, respectively. Sensitivity for upE is 3.4 copies per reaction (95% confidence interval (CI): 2.5-6.9 copies) or 291 copies/mL of sample. No cross-reactivity was observed with coronaviruses OC43, NL63, 229E, SARS-CoV, nor with 92 clinical specimens containing common human respiratory viruses. We recommend using upE for screening and ORF1b for confirmation. .

Loading

Article metrics loading...

/content/10.2807/ese.17.39.20285-en
2012-09-27
2024-12-26
/content/10.2807/ese.17.39.20285-en
Loading
Loading full text...

Full text loading...

/deliver/fulltext/eurosurveillance/17/39/art20285-en.htm?itemId=/content/10.2807/ese.17.39.20285-en&mimeType=html&fmt=ahah