Rapid communication Open Access
Like 0

Abstract

Three German patients developed nosocomial pneumonia after cardiac surgery and had complex detected in respiratory specimens. Two patients died of septic multi-organ failure. Whole-genome sequencing detected genetically identical complex strains in patient samples, from a batch of octenidine mouthwash solution, which had been used for nursing care, as well as in samples obtained from the manufacturer during production. Contamination of medical products during manufacturing may lead to international outbreaks.

Loading

Article metrics loading...

/content/10.2807/1560-7917.ES.2018.23.42.1800540
2018-10-18
2024-11-23
http://instance.metastore.ingenta.com/content/10.2807/1560-7917.ES.2018.23.42.1800540
Loading
Loading full text...

Full text loading...

/deliver/fulltext/eurosurveillance/23/42/eurosurv-23-42-2.html?itemId=/content/10.2807/1560-7917.ES.2018.23.42.1800540&mimeType=html&fmt=ahah

References

  1. European Nucleotide Archive (ENA). World’s nucleotide sequencing information. Cambridge: ENA; 2018. Available from: http://www.ebi.ac.uk/ena
  2. Sfeir MM. Burkholderia cepacia complex infections: more complex than the bacterium name suggest. J Infect. 2018;77(3):166-70.  https://doi.org/10.1016/j.jinf.2018.07.006  PMID: 30012345 
  3. Ahn Y, Kim JM, Lee YJ, LiPuma JHussong D, Marasa B, et al. Effects of extended storage of chlorhexidine gluconate and benzalkonium chloride solutions on the viability of Burkholderia cenocepacia. J Microbiol Biotechnol. 2017;27(12):2211-20.  PMID: 29032643 
  4. Song JE, Kwak YG, Um TH, Cho CR, Kim S, Park IS, et al. Outbreak of Burkholderia cepacia pseudobacteraemia caused by intrinsically contaminated commercial 0.5% chlorhexidine solution in neonatal intensive care units. J Hosp Infect. 2018;98(3):295-9.  https://doi.org/10.1016/j.jhin.2017.09.012  PMID: 28935523 
  5. Dolan SA, Dowell E, LiPuma JJ, Valdez S, Chan K, James JF. An outbreak of Burkholderia cepacia complex associated with intrinsically contaminated nasal spray. Infect Control Hosp Epidemiol. 2011;32(8):804-10.  https://doi.org/10.1086/660876  PMID: 21768765 
  6. Gravel-Tropper D, Sample ML, Oxley C, Toye B, Woods DE, Garber GE. Three-year outbreak of pseudobacteremia with Burkholderia cepacia traced to a contaminated blood gas analyzer. Infect Control Hosp Epidemiol. 1996;17(11):737-40.  https://doi.org/10.2307/30141546  PMID: 8934241 
  7. Jacobson M, Wray R, Kovach D, Henry D, Speert D, Matlow A. Sustained endemicity of Burkholderia cepacia complex in a pediatric institution, associated with contaminated ultrasound gel. Infect Control Hosp Epidemiol. 2006;27(4):362-6.  https://doi.org/10.1086/503343  PMID: 16622813 
  8. Marquez L, Jones KN, Whaley EM, Koy TH, Revell PA, Taylor RS, et al. An outbreak of Burkholderia cepacia complex infections associated with contaminated liquid docusate. Infect Control Hosp Epidemiol. 2017;38(5):567-73.  https://doi.org/10.1017/ice.2017.11  PMID: 28166854 
  9. Glowicz J, Crist M, Gould C, Moulton-Meissner H, Noble-Wang J, de Man TJB, et al. A multistate investigation of health care-associated Burkholderia cepacia complex infections related to liquid docusate sodium contamination, January-October 2016. Am J Infect Control. 2018;46(6):649-55.  https://doi.org/10.1016/j.ajic.2017.11.018  PMID: 29329922 
  10. De Smet B, Veng C, Kruy L, Kham C, van Griensven J, Peeters C, et al. Outbreak of Burkholderia cepacia bloodstream infections traced to the use of Ringer lactate solution as multiple-dose vial for catheter flushing, Phnom Penh, Cambodia. Clin Microbiol Infect. 2013;19(9):832-7.  https://doi.org/10.1111/1469-0691.12047  PMID: 23173820 
  11. Souza Dias MB, Cavassin LG, Stempliuk V, Xavier LS, Lobo RD, Sampaio JL, et al. Multi-institutional outbreak of Burkholderia cepacia complex associated with contaminated mannitol solution prepared in compounding pharmacy. Am J Infect Control. 2013;41(11):1038-42.  https://doi.org/10.1016/j.ajic.2013.01.033  PMID: 23663863 
  12. Lalitha P, Das M, Purva PS, Karpagam R, Geetha M, Lakshmi Priya J, et al. Postoperative endophthalmitis due to Burkholderia cepacia complex from contaminated anaesthetic eye drops. Br J Ophthalmol. 2014;98(11):1498-502.  https://doi.org/10.1136/bjophthalmol-2013-304129  PMID: 24947905 
  13. Singhal T, Shah S, Naik R. Outbreak of Burkholderia cepacia complex bacteremia in a chemotherapy day care unit due to intrinsic contamination of an antiemetic drug. Indian J Med Microbiol. 2015;33(1):117-9.  https://doi.org/10.4103/0255-0857.148405  PMID: 25560013 
  14. Shrivastava B, Sriram A, Shetty S, Doshi R, Varior R. An unusual source of Burkholderia cepacia outbreak in a neonatal intensive care unit. J Hosp Infect. 2016;94(4):358-60.  https://doi.org/10.1016/j.jhin.2016.07.008  PMID: 27613440 
  15. Alvarez-Lerma F, Maull E, Terradas R, Segura C, Planells I, Coll P, et al. Moisturizing body milk as a reservoir of Burkholderia cepacia: outbreak of nosocomial infection in a multidisciplinary intensive care unit. Crit Care. 2008;12(1):R10.  https://doi.org/10.1186/cc6778  PMID: 18237375 
  16. Sommerstein R, Führer U, Lo Priore E, Casanova C, Meinel DM, Seth-Smith HM, et al. Burkholderia stabilis outbreak associated with contaminated commercially-available washing gloves, Switzerland, May 2015 to August 2016. Euro Surveill. 2017;22(49).  https://doi.org/10.2807/1560-7917.ES.2017.22.49.17-00213  PMID: 29233255 
  17. Martin M, Winterfeld I, Kramme E, Ewert I, Sedemund-Adib B, Mattner F. Ausbruch mit Burkholderia-cepacia-Komplex durch kontaminierte Mundspüllösung. Anaesthesist. 2012;61(1):25-9.  https://doi.org/10.1007/s00101-011-1954-4  PMID: 22273822 
/content/10.2807/1560-7917.ES.2018.23.42.1800540
Loading

Data & Media loading...

Submit comment
Close
Comment moderation successfully completed
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error